Home  >  Air Conditioners  >  

new Ultrasonic Humidifier/manufacturer - MD-868

2011new Ultrasonic Humidifier, 1).Mist size can be different according to their own skin to adjust, 2).Dry automatic protection - more info check here: http://www.sourcingappliances.com/new-Ultrasonic-Humidifier-manufacturer-11090578/

Quick Brief

Type: Ultrasonic Humidifier Installation: Tabletop / Portable Mist Output (gallon / day): 1 Power (W): 20 Voltage (V): 220 Place of Origin: Guangdong China (Mainland) Model Number: MD-868 Brand Name: OEM Capacity: 1.2L Humidity Control: Manual Color: Azure Mist Output: 200ml/h material: PP&ABS n.w/g.w: 0.7/0.9kgs ultrasonic humidifier: air humidifier

Product Features:

2011new Ultrasonic Humidifier

1).Mist size can be different according to their own skin to adjust

2).Dry automatic protection

Business Terms:

Port: Guangzhou

Minimum Order Quantity: 2400 Piece/Pieces

Supply Ability: 50000 Piece/Pieces per Month

Payment Terms: T/T

Contact Supplier
new Ultrasonic Humidifier/manufacturer
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: size of giftbox: 170*170*613mm size of ctn: 700*360*660mmqty/ctn: 16pcs

Delivery Detail: within 20days

Specifications and Product Details:

ultrasonic humidifier

Features:

A. Unique design, Humidifying decorate double use

B.Low water indicator,power off automatic when waterless

C.Low power consumption,Eco-friendly

D.slient coperation, Durable

E.Easy to coperate and clean

Precautions

A.Safety precautions

1. Do not unplug with your wet hand, otherwise there might be the risk of electric shock

2. When the body is inclined, please handle this with the power cut off

3.Do not touch the transducer when the product is working, otherwise you will have the feel of pain

4.Do not disassemble the unit without cutting off the power to avoid an electric shock

5. The power cord can not be scratched, damaged, over-bent, dragged, twisted, tied a knot, and do not dress weight, clamp or process, otherwise it will make you feel painful

6. Do not let the children to operate this machine

7.This product is used only for indoor

8.When the power cord is damaged, it should be replaced by the professional of manufacturer of retailer with a same standard power cord, please do not replace by yourself.

B.operation precautions

Please abide by the following safety precautions when you are using this Humidifier.

1. Please read all the instructions even if you are familiar with this product very much

2. Before switch on, please check if the voltage you are using

3. Please do not use this product near the heat

4. Please do not put this product at a place that hard light or hot wind can radiate.

5. Do not place humidifier at the air inlet, and try to make it far from other electric product.

6. Do not pour hot water that is higher than 40 centigrade into the water tank or water bath, which will prevent it from discolored or transformative

7. Do not let water flow into the body from the air outlet. Wipe off any water outside the body with dry cloth.

8. Please empty the water bath and water tank when the indoor temperature is below 0 °C, lest the icing of water should damage the components

9. Do not put any metals, chemicals or detergents into the water bath. Otherwise there might be poor atomization

10.Do not move it at a random when there is not much water in the water bath, otherwise the water might overflow and flow into the body and cause troubles

11. Please do not pour water into the water bath directly

12. Please cut off the power and unplug when this unit is not to be used at a long time. This unit does not have to be grounded

13.Never pour out the water remaining in the water bath without the power turned off. Otherwise the transducer will burned out immediately.

14. Do not overturn the body when it needed to add water.

15. Please switch off and unplugged before cleaning or moving the humidifier.

16. This product is only used as what this manual stated, no other usages

Cleaning and Maintenance

Note: Please be sure to switch off and unplug before cleaning

1.Cleaning of water tank (once every2-3weeks)

Screw the water tank cover off, wipe the scale off and rinse it

2.Cleaning of water bath (once a week)

If there are any scale in the water bath, wipe it off with a soft cloth that are dipped with cleanser and rinse it with water

3.External cleaning of humidifier

Rinse the soft cloth in warm water that are lower than 40°C ,wipe the stain off on the surface. The spray nozzle can be flushed by water directly

4. Cleaning of atomizer

You can drop some citric acids on the scale that stick to the surface of the atomizer and wipe with swab or brush, then rinse it with water

5.Humidifier storage

Please clean, pack it after airing and put it in a dry place when it’s no to be used at a long time

new Ultrasonic Humidifier/manufacturer suppliers    new Ultrasonic Humidifier/manufacturer manufacturers