1.Thermal protector for universal motor, window lift & wiper
2. Equivalent to Sensata 6AP or Otter
3. Min trip current:1.2A
Price Terms:FOB,CIF,EXW
Payment Terms: T/T,Western Union,MoneyGram,L/C
Minimum Order: Negotiatable
Delivery Port: Customized
Contact SupplierPackaging Detail: 20000 pcs per paper carton; carton size: 17cm * 20cm * 31cm
Delivery Detail: 10 working days
6APE series is a current sensitive thermal protector. Also called window lift thermal protectors, or wiper thermal protectors. They can protect motor of window lift or wiper from over loading and will disconnect the power supply during prescribed period. It has the same functions as Sensata thermal protector 6AP or Otter thermal cutout PB or G series.
* Special Features of thermal protectors:
1. Small size, long life and high reliability
2. High quality level bimetal ensures that it can withstand the current of normal circuit.
3. The combination of bimetal and heater can action snappily.
4. Accurate trip off time can prevent motor from overheating or loading;
5. Both temperature and current sensitive.
6. Terminals are optional and customizing
7. Wires are optional and customizing
* Electrical Ratings of 6APE thermal protector:
Item | Votage | Current |
1 | 15VDC | 30A |
2 | 30VDC | 15A |
Life cycles | 30,000 | 30,000 |
* Technical Parameters of thermal protectors:
Action temperature: | 50-180°C |
Tolerance | ±5°C |
Trip Off current: | 1.5-32 Amp |
Trip Off time | 4~10S |
* Applications of thermal protectors:
1. Window lift motor, skylight motor, aerial motor, and wiper motor
2. Various engines, dc motors, juicer motors
3. Various washing machines, vacuum cleaners and gardening equipments
* Type Classification of thermal protector:
1. Type 2B: Automatic Control, micro-disconnection on operation, and, manufacturing deviation and drift of its operating value, operating time or operating sequence have been declared and tested.
2. Type 3C: for thermal motor protector only
* Crucial tests and relevant methods of thermal protector:
1. Electric strength: Test voltage 1250VAC 50HZ applied between insulation sleeve and live parts, and 500VAC applied between two opened contacts, for 1 minute, no flashover or breakdown.
2. Endurance test: Number of automatic cycles declared as 10,000 cycles, the test shall be carried out under 1.15 VR for 200 cycles, the balance 9800 cycles should be carried out under rated voltage
3. Moisture resistance test:
Humidity Treatment: Relative humidity(%): 91-95%; Temperature: (20-30+/-1) C degree
Keep samples under this environment for 48 hours. No damage so as to impair compliance with this standard.
4. Manufacturing deviation:
The appropriate operating value or operating sequence shall be recorded for each sample. No two samples shall differ from each other by an amount exceeding the declared manufacturing deviation.
Tolerance of trip-off temperature: +/-5K
The temperature of oven may be rapidly increased to 10K below the expected operating temperature. Rate of temperature change reduced to max 0.5K/min or as declared.
5. Synchorous test:
5 minutes continuous operation test, no flicking occurs.
6. Relevant Standard number:
EN60730-1, EN60730-2-9; EN60730-2-2; UL 873; UL2111
* Dimensional Drawings of thermal protectors
* Clear photo