High pressurized double coil water tank with Auxiliary electric heating design
Port: Shanghai
Minimum Order Quantity: 1 Piece/Pieces
Supply Ability: 5000 Piece/Pieces per Month
Payment Terms: L/C,T/T
Contact SupplierPackaging Detail: Carton
Delivery Detail: 15-30 days
1. Double coil Water tank , transfer heat energy collected by the solar collector to heat exchanger rapidly, which made tank temperature rising stable
2. Double coils and Auxiliary electric heating design, make water tank auxiliary heating system flexible, hours hot water
3. SUS 304 foog grade stainless steel inner tank,with Automatic argon arc welding and preservative treatment welding, which make Donper hot water tank has higher antiseptic power than Enameled water tank.
4. Higher pressure resistance, which can bear 0.8Mpa water tank pressure, more comfortable bathing.
Model | PH2-200 | PH2-300 | PH2-400 | PH2-500 | |
Rated capacity(L) | 200 | 300 | 400 | 500 | |
Rated pressure(MPa) | 0.8 | 0.8 | 0.8 | 0.8 | |
Maximum operating temperature(°C) | 90 | 90 | 90 | 90 | |
Inner tank material | SUS 304-2B | SUS 304-2B | SUS 304-2B | SUS 304-2B | |
Outer tank material | Color steel plate | Color steel plate | Color steel plate | Color steel plate | |
Matching heat collecting area (m²) | 2.8 | 4.2 | 5.6 | 7.0 | |
Electric heating power(kW) | 2 | 2 | 3 | 3 | |
Heat exchanger area (m²) | upper coil | 0.85 | 1 | 1.2 | 1.5 |
lower coil | 0.85 | 2 | 2 | 2.5 | |
Coil heat exchanger rated pressure(MPa) | 0.8 | 0.8 | 0.8 | 0.8 | |
Coil heat exchanger material | SUS 304-2B | SUS 304-2B | SUS 304-2B | SUS 304-2B | |
Coil heat exchanger capacity(L) | upper coil | 3.8 | 4.8 | 6.1 | 7.4 |
lower coil | 3.8 | 9.1 | 9.8 | 11.6 | |
Coil heat exchanger Max. Hydraulic Flow(m3/h) | 3 | 3 | 3 | 3 | |
optimum heat exchange Temperature of heat exchanger(°C) | 80 | 80 | 80 | 80 | |
Package dimension(mm) | 760×760×1490 | 760×760×2030 | 860×860×1750 | 860×860×2070 |