1) big air flow ,low noise
2) Brazil Class C with INMETRO
3) auto-restart function
4).Energy-saving
5)high efficiency
Price Terms:FOB,CIF,EXW
Payment Terms: T/T,Western Union,MoneyGram,L/C
Minimum Order: Negotiatable
Delivery Port: Customized
Contact SupplierPackaging Detail: Standard Export Carton
Delivery Detail: 35 to 40 working days after confirming your L/C or T/T payment
Power supply | Ph-V-Hz | 1Ph, 220-230V~, 60Hz | ||
Cooling | Capacity | Btu/h | 9000 | |
Input | W | 940 | ||
Rated current | A | 4.3 | ||
EER | W/W | 2.81 | ||
Heating | Capacity | Btu/h | 9000 | |
Input | W | 840 | ||
Rated current | A | 3.8 | ||
COP | W/W | 3.1 | ||
Moisture Removal | L/h | 1.0 | ||
Max. input consumption | W | 1300 | ||
Max. current | A | 6.5 | ||
Starting current | A | ---- | ||
Compressor | Model | PH130M1C-3DZDU1 | ||
Type | ROTARY | |||
Brand | TOSHIBA | |||
Thermal protector | B185-135-141C | |||
Thermal protector position | EXTERNAL | |||
Capacitor | uF | 30 | ||
Refrigerant oil/oil charge | ml | SUNISO 4GSD/ATMOS NM56EP •350 | ||
Indoor fan motor | Model | RPG20B | ||
Brand | Welling | |||
Input | W | 43 | ||
Capacitor | uF | 1.5 | ||
Speed(Hi/Mi/Lo) | r/min | 1150/1000/850 | ||
Indoor coil | a.Number of rows | 2 | ||
b.Tube pitch(a)x row pitch(b) | mm | 21x13.37 | ||
c.Fin spacing | mm | 1.3 | ||
d.Fin type (code) | Hydrophilic aluminium | |||
e.Tube outside dia.and type | mm | 7, innergroove tube | ||
f.Coil length x height x width | mm | 637x273x26.67 | ||
g.Number of circuits | 2 | |||
Indoor air flow (Hi/Mi/Lo) | m3/h | 510/450/380 | ||
Indoor noise level (Hi/Mi/Lo) | dB(A) | 40/37/34 | ||
Indoor unit | Dimension(W*D*H) | mm | 790x190x275 | |
Packing (W*D*H) | mm | 865x265x350 | ||
Net/Gross weight | Kg | 8.5/10.5 | ||
Outdoor fan motor | Model | YDK30-6B | ||
Brand | Welling | |||
Input | W | 74 | ||
Capacitor | uF | 2.5 | ||
Speed | r/min | 860 | ||
Outdoor coil | a.Number of rows | 1 | ||
b.Tube pitch(a)x row pitch(b) | mm | 21x13.37 | ||
c.Fin spacing | mm | 1.4 | ||
d.Fin type (code) | Hydrophilic aluminium | |||
e.Tube outside dia.and type | mm | 7, innergroove tube | ||
f.Coil length x height x width | mm | 694x504x13.37 | ||
g.Number of circuits | 2 | |||
Outdoor air flow | m3/h | 1650 | ||
Outdoor noise level | dB(A) | 56 | ||
Outdoor unit | Dimension(W*D*H) | mm | 700x235x535 | |
Packing (W*D*H) | mm | 815x325x580 | ||
Net/Gross weight | Kg | 24/26 | ||
Refrigerant type | g | R22/560g | ||
Design pressure | MPa | 2.6/1.0 | ||
Refrigerant piping | Liquid side/ Gas side | mm(inch) | 6.35/9.53(1/4"/3/8") | |
Max. refrigerant pipe length | m | 10 | ||
Max. difference in level | m | 5 | ||
Connection wiring | 1.31(Optional) | |||
Plug type | AWG16x3/SP008 | |||
Thermostat type | Remote control | |||
Operation temp | °C | 17-30 | ||
Ambient temp (cooling/heating) | °C | 18-43/-7-24 | ||
Application area |
| 13-22 | ||
Qty’per 20’ /40’ /40'HQ | 121/254/292 |