Solar collector evacuated tubes collect and convert sunshine energy into thermal energy, which is transferred to the central heat pipes in the tubes through the aluminum fins bridging the tube inner surfaces and the heat pipes. The copper heat pipes have tiny amount of purified water sealed in them at depressurized condition. When heated, the water inside the heat pipes vaporizes at low temperature . The vapor (steam) rises to the pipe tips inserted into the water contained in the tank. Vapor is cooled down and becomes condensate falling to the bottom of the pipes. By continuously circulating this way, heat is carried from outside to the water inside the tank.
Advantages:
Highly efficient absorber of high performance with daily average efficiency over 50%;
Start up quickly, heat pipe transfer the heat energy into the storage tank in one direction.
Withstand pressure of 6 Bar, can be connected directly with city water.
No water inside the evacuated tubes; the solar water heater can still in service even with several tubes breakage;
Highly efficient insulation with polyurethane foam;
Heat PipeVacuum Tube
Tube size(mm): 47*1500mm 58*1800 mm
Tube Nos.(pcs): 15 / 18 / 20 / 24 / 30 / 36
Vacuum tube material: Borosilicate glass, red copper heat pipe, aluminum fin
Coating material: Cu/SS-ALN(H)/SS-ALN(L)/ALN coating
Water tank
Capacity: 100 ~ 300L
Inner tank: Food-grade SUS304-2B stainless steel
Insulation: Imported polyurethane Integrated-foaming 50-65mm
Tank shell: Color steel plate / Fluorocarbon plate (PVDF)
Main technical data about solar controller:
1. Externality size: 450*200*150mm
2. Max. Self consumption: ≤3W
3. Accuracy of temprature measuring: +-2C
4. Range of temperature measuring: 0-99C
5. Power of circulation pump: (temperature difference circulation pump, water-using end circulation pump): <600W
6. Auxiliary heating power: ≤2000W
7. System working pressure: 0.6Mpa
8. Inputsignals: 3 temperature sensors(for top of tank, for bottom of tank, for collector)
9. Output signals: 3(electronic booster, temperature difference circulation pump and water-using end circulation pump)
Main Functions:
1. Display clock and weekday
2. Display temperature
3. Temperature difference circulation pump provides there speed leverls
4. Temperature difference circulation
5. Three periods timing circulation for pipeline
6. There periods timing heating(or tank)
7. Frost protection
8. Memory function
9. Set tank temperature
10. Display flux
11. Disply system pressure
12. Storage tank overheating protection