Air source heat pump boiler
1.High efficiency
2.Built in water pump
3.R407c&R410a
4.Connect with exist water tank
Port: Shenzhen
Minimum Order Quantity: 1 Unit/Units sample exception
Supply Ability: 2000 Set/Sets per Month
Payment Terms: L/C,T/T
Contact SupplierPackaging Detail: wood carton
Delivery Detail: 30 working days
Top rated Air source heat pump boiler water heater(with water pump built in)
This series of Domestic Air/Water Heat Pump adopts high efficiency tube-in shell heat exchanger and built in water pump inside, which ensures not only high efficiency performance of the system but also easy installation work. Just simply connect the heat pump unit to the water tank through water piping.
1. Built-in highly efficient tube-in-shell heat exchanger and WILO water pump.
2. Compact design, more easy for installation, less space taken
3. High efficiency auto defrosting with revert circuit.
Extensive application:
It is suitable for family, villa, apartment, high-floor residence, business restaurant, for heating and sanitary hot water use .
Model | KF80-B | KF120-B | KF240-B | KF400-B | KF480-B | |
HP | 1 | 1.5 | 3 | 5 | 6 | |
Heating capacity | kW | 3.71 | 5.58 | 11.6 | 19.1 | 18.1 |
BTU/h | 12659 | 19039 | 39579 | 65169 | 61757 | |
COP | 4.12 | 4.46 | 4.64 | 4.24 | 4.11 | |
Rated heated water output | L/h | 80 | 120 | 240 | 400 | 480 |
Rated outlet water temp. | °C | 55 | ||||
Max outlet water temp. | °C | 60 | ||||
Rated power input | kw | 0.9 | 1.25 | 2.5 | 4.5 | 4.4 |
Rated current | A | 3.73 | 5.89 | 11.36 | 6.45 | 25.2 |
Power supply | V/PH/Hz | 220V/1N~/50Hz | 380V/3N~/50Hz | |||
Compressor | type | Rotary | Scroll | |||
Number | 1 | 1 | 1 | 1 | 2 | |
Heat exchanger type | Number | High efficiency tube in shell heat exchanger | ||||
Throttling device | Capillary | Emerson thermal expansion valve | ||||
Fan | type | Low noise high efficiency axial type | ||||
discharging | Horizontal | Horizontal/Vertical | Vertical | |||
quantity | 1 | 1 | 1 | 2 | 2 | |
Power input/W | 20 | 20 | 50 | 90 | 160 | |
speed/RPM | 830 | 830 | 850 | 850 | 850 | |
Ambient temperature | °C | (-10°C~43°C) | ||||
Refrigerant | R22/R410A | R22/R407C | ||||
Noise in 1 meter distance | dB | ≤54dB(A) | ≤54dB(A) | ≤59dB(A) | ≤62dB(A) | ≤62dB(A) |
Water pipe size | inch | Rc3/4 | Rc3/4 | R1 | R1 | R1-1/2 |
Suggested water tank capacity | L | 100-150 | 200-300 | 300-500 | 500 | 500 |
Cabinet | Stainless steel | |||||
Low pressure protection system | Yes | |||||
High pressure protection system | Yes | |||||
Water flow switch | No | |||||
Automatical defrost system | Yes | |||||
Product Dimension | mm | 710/310/940 | 710/310/940 | 800/400/1220 | 1110/530/1260 | 1430/700/860 |
(left-right)mm | 930/360/560 | 930/360/560 | 760/700/860 | |||
Package dimension | mm | 850/450/1020 | 850/450/1020 | 950/550/1400 | 1260/680/1430 | 1570/840/1050 |
(left-right)mm | 1080/450/660 | 1080/450/660 | 900/830/1050 | |||
Net wieght | kg | 55 | 62 | 110 | 155 | 190 |
(left-right)mm | 48 | 55 | 95 | |||
Gross weight | kg | 67 | 74 | 134 | 178 | 249 |
(left-right)mm | 58 | 65 | 139 | |||
Testing condition: Ambient temp.(DB/WB) = 20°C/ 15 °C, Inlet/outlet water temp. = 15°C/55°C |