Temperature and pressure relief valve - T/P relief valve

T/P valve, 1,Function: relief pressure, 2,Use:Pressurized water heater, 3,Pressure range: 0.1MPA,0.3,0.5,0.6,0.7,0.86,1.0MPA - more info check here: http://www.sourcingappliances.com/Temperature-and-pressure-relief-valve-11056523/

Quick Brief

Type: Solar Water Heater Parts Place of Origin: China (Mainland) Brand Name: T/P relief valve Model Number: T/P relief valve Function: Relief valve Use: pressurized water heater Material: brass pressure range: 3bar to 10bar

Product Features:

T/P valve

1,Function: relief pressure

2,Use:Pressurized water heater

3,Pressure range: 0.1MPA,0.3,0.5,0.6,0.7,0.86,1.0MPA

Business Terms:

Port: Shanghai port

Minimum Order Quantity: 1 Piece/Pieces

Supply Ability: 1000000 Piece/Pieces per Year

Payment Terms: T/T

Contact Supplier
Temperature and pressure relief valve
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: cartons

Delivery Detail: 7days

Specifications and Product Details:

T&P Valve

1, Commodity name: Temperature and Pressure Relief Valve

2, Use:T&P Valve for solar water heater, electric heater and so on

3, T&P relief Valve Function:

The T&P valve is designed to relieve the increase in pressure which develops during the normal heating cycle.

This is caused by the water expanding during the heating cycle.The T/P valve then will relieve the increase in pressure by releasing drips of hot water to the drain line. It is recommended that an expansion control valve be fitted to the cold water supply line as it will relieve cold water(not hot water),during the heating cycle expansion,thereby saving energy and increasing the life of the T&P relief valve.Local regulations may make it mandatory to install an expansion control valve in the cold water supply line.

Should the electrical temperature cut-out devices cease to operate correctly,the water will overheat and the temperature probe will then be activated to open the P/T valve,discharging hot water.

4, T/P relief valve for solar water heater

Inlet pressure control:

High pressure may cause excessive discharge and possible premature failure of the operating relief valve.The maximum water pressure usually occurs during the night, at the time of lowest water usage. In any mains pressure water heater installation,if the inlet water pressure exceeds 80% of the nominal set pressure of the operation relief valve,a pressure limiting valve must be fitted to the cold inlet.(If a cold water expansion control valve is fitted it will have a lower set pressure than the T/P relief valve and thus be classed as the "operating"relief valve.)

5,T&P Valve Installation:

T/P Valves should be installed by a licensed plumber.

If the temperature probe protruding from inside the inlet thread is damaged or bent,do not install,and obtain a replacement valve.

Clean out all deposits from the threaded boss on the heater before fitting a replacement valve,otherwise the new valve risks contamination and premature failure.Apply PTFE thread tape to the male taper thread,making sure that the tape does not hang over the outer end of the thread,as this can lead to premature valve failure.Screw the valve into the heater socket.Do not use a wrench on the valve body.Use teh hexagonal spanner flats provided.No valves,taps,or other isolating devices are to be fitted between the P&T relief valve and the water heater.

Install a drain line of the same nominal size as the valve(The drain line must have a continuous fall.)