Home  >  Water Heaters  >  Solar Water Heaters

Split Pressurized Solar Water Heater - MXE-SWH-280

split pressurized solar water heater, 1.CE,ISO90001,CCC certificate, 2.10 years quality warrany, 3.delivey:15 days, 4.offer OEM - more info check here: http://www.sourcingappliances.com/Split-Pressurized-Solar-Water-Heater-11059758/

Quick Brief

Type: Evacuated Tube Pressure: Pressurized Circulation Type: Indirect / Closed Loop (Activ... Heating System: Batch / ICS (Passive) Connection Type: Split Installation: Wall Mounted Housing Material: Stainless Steel Certification: CE, CCC,ISO9001,ISO14001 Capacity: 300 Place of Origin: Zhejiang China (Mainland) Brand Name: MICHER Model Number: MXE-SWH-280 solar water heater: split pressurized solar wat...

Product Features:

split pressurized solar water heater

1.CE,ISO90001,CCC certificate

2.10 years quality warrany

3.delivey:15 days

4.offer OEM

Business Terms:

Port: Shanghai/Ningbo

Minimum Order Quantity: 1 Set/Sets

Supply Ability: 25,000 Set/Sets per Month

Payment Terms: L/C,T/T,Western Union

Contact Supplier
Split Pressurized Solar Water Heater
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: Sample: Wooden boxContainer: Strong standard export carton

Delivery Detail: 15 days

Specifications and Product Details:

split pressurized solar water heater

Details: 1. Dimension of vacuum tubes: 47mm, 58mm diameter 1.5m, 1.8m length

2. Evacuated tube: Borosilicate glass 3.3

3. Absorbing rate >93%

4. Number of tubes: 15-36

5. Out tank shell: Color armor plate /stainless steel

6. Inner tank: SUS 304 2B food grade stainless steel

7. Insulating layer: 50mm /55mm /60mm/70mm import PU without Fluorin

8. Frame: Galvanized sheet power coated/stainless steel/aluminium sheet angle: 30/38/45

9. Seal: Silicone rubber

10. Fast pieces: Stainless steel screw

Comparison Sheet Evacuated Heat Pipe Collectors Versu Flat-Plate Solar Panels

Evacuated Heat Pipe TubesFlat-plate Solar Panels
The collector is hermetically sealed inside an evacuated glass tube, eliminating convection and conduction heat losses and isolating the collector from adverse ambient conditions. Therefore, no heat losses due to convection and conduction and no change of performance during the service life of the collector due to corrosion.The collector is put in a casing with a glass shield to reduce heat losses. The air gap between absorber and cover pane allows heat losses to occur, especially during cold and windy days. Build up of condensation will in due course influence the collector greatly due to corrosion, reducing performance and durability.
Uses a heat-pipe for super efficient heat
conduction. No water enters into the collector.
Circulates water inside insulated areas. Prone to leakage, corrosion and restriction of flow due to possible air lock.
The heat-pipe has a self-limitation of maximum
working temperature through the physical
properties of its special fluid (THS200 and THS250
models) resulting in safeguarding the system and
system fluid (water and anti-freeze mixture).
Flat-plate collectors have no internal method of limiting heat build up and have to use outside tempering devices. When these safety or control devices fail the system and/or system-fluid can be destroyed.
Thermal diode operation principle. The heat pipe’s thermal flows one way only; form the collector to the water and never in the reverse.Flat-plates can actually rob the water of built up heat if the collector becomes colder than the water temperature.
Corrosion and freeze free; there is nothing within the evacuated tube to freeze and the hermetic sealing of each tube eliminates corrosion.Flat-plate collectors contain water and unless well-protected can burst upon freezing. Corrosion can become a major problem reducing performance!
Easy installation and no maintenance. Lightweight individual collector tubes are assembled into the system at the point of installation. Each tube is an independently sealed unit requiring no maintenance.Installation is difficult. Entire panels have to be hoisted onto the roof and installed. if one has a leak, the entire collector has to be shut down and removed.
Relatively insensitive to placement angle, allowing architectural and aesthetic freedom.Requires accurate southern exposure and elevation placement.

Specification of our products:

modeldiameter of vacuum tubelength of vacuum tubeQty of vacuum tubeeffective heating areacapacity of tankApplication people no.
MXE-SSMP-58-1.8-1858mm1800mm182.48m²150L3-4
MXE-SSMP-58-1.8-2458mm1800mm243.30m²200L4-5
MXE-SSMP-58-1.8-3058mm1800mm304.13m²250L5-6
MXE-SSMP-58-1.8-3658mm1800mm18*24.95m²300L6-7
MXE-SSMP-58-1.8-4858mm1800mm24*26.60m²400L8-9
MXE-SSMP-58-1.8-6058mm1800mm30*28.26m²500L10-12

Split Pressurized Solar Water Heater suppliers    Split Pressurized Solar Water Heater manufacturers