1.DC Inverter air to water heat pump
2.-25DegC-43DegC
3.Heating and cooling
4.High efficient defrosting
5.LED panel
Price Terms:FOB,CIF,EXW
Payment Terms: T/T,Western Union,MoneyGram,L/C
Minimum Order: Negotiatable
Delivery Port: Customized
Contact SupplierPackaging Detail: plywood/compressing hard paper
Delivery Detail: 20days
Features:
1.DC Inverter air to water heat pump
2.Welldone in super cold weather between -25°C and 43°C3.
3.Heating and cooling function
4.High efficient defrosting
5.LED panel welldone
World famous components:
Matsushita compressor,Rotary,R410A,environmentally friendly
Japanese electronic expansion valve
Item:Split DC Inverter air to water heat pump
Model | DRSDC12 | DRSDC24 | DRSDC48 | DRSDC50 | |
Power supply | 220~240V/50Hz/1Ph | ||||
Refrigerant | R410A | ||||
Cooling capacity | Btu/h | 3400-15600 | 8800-27300 | 17600-54600 | 11942-44356 |
W | 1000-4600 | 2600-8000 | 5200-16000 | 3500-13000 | |
Heating capacity | Btu/h | 4400-17500 | 11600-30700 | 23200-61400 | 24907-61416 |
W | 1400-5270 | 3400-9000 | 6800-18000 | 7300-18000 | |
Input power(cooling) | W | 495-1650 | 1100-3500 | 2200-7000 | 1500-5600 |
Input power(heating) | W | 500-1650 | 1050-2800 | 2100-5600 | 1850-5700 |
Input Current(cooling) | A | 2.2-7.5 | 5-15.5 | 10-31 | 2.3-8.5 |
Input Current(heating) | A | 2.2-7.4 | 4.7-12.5 | 9.4-25 | 2.8-8.66 |
E.E.R | Btu/h-W | 7.0-12.0 | 7.8-11.0 | 7.81-11.0 | 7.96-12.3 |
C.O.P | W/W | 2.4-3.65 | 2.6-3.8 | 2.6-4.5 | 3.2-4.3 |
Compressor | Inverter Rotary | Twin Rotary | Twin Rotary | Twin Rotary | |
Fan | |||||
Type | Axial | Axial | Axial | Axial | |
Qty | 1 | 1 | 2 | 1 | |
Airflow | m³/h | 1750 | 4400 | 7500 | 7500 |
Rated power | W | 85 | 160 | 320 | 320 |
Heat exchanger(air side) | |||||
Type | tube-fin | tube-fin | tube-fin | tube-fin | |
Face area | m² | 0.395 | 0.705 | 1.41 | 1.3 |
Row-fins/in | 2 rows-14 | 2 rows-14 | 2-(2 rows-14) | 2 rows-14 | |
Tube Dia | Inch | 3/8 O.D. | 3/8 O.D. | 3/8 O.D. | 3/8 O.D. |
Noise level indoor/outdoor | Db(A) | 35/46 | 29/56 | 35/56 | 35/56 |
Heat exchanger(water side) | |||||
Type | tube in tube | high efficiency tube in shell | plate heat exchanger | plate heat exchanger | |
Water pressure drop | kPa | 8 | 8 | 5 | 5 |
Piping connection | Inch | G3/4" | G3/4" | G3/4" | G1" |
Water pump | |||||
Max water flow | m³/h | 0.65 | 1.3 | 3 | 3 |
Remark:1.cooling condition:water in/out temp. 12°C/7°C,ambient temp.35°C; | |||||
2.heating condition:water in/out temp.40°C/45°C.ambient temp.DB7°C/WB6°C | |||||
The specifications are subject to change without prior notice, for actual pecifications of unit,please refer to the stickers on the unit. |