Home  >  Water Heaters  >  Solar Water Heaters

Manufacture since 1998,Split pressurized heat pipes Solar Water System(SLCLS) With CE,BV,SGS,CCC Approved - SLCLS

1)Split pressurized heat pipes Solar Water System, 2) Manufacture since 1998, 3) Free training, no worry - more info check here: http://www.sourcingappliances.com/Manufacture-since-1998-Split-pressurized-heat-pipes-Solar-Water-System-SLCLS-With-CE-BV-SGS-CCC-Approved-10130661/

Quick Brief

Type: Evacuated Tube Pressure: Pressurized Circulation Type: Indirect / Closed Loop (Activ... Heating System: Thermosyphon (Passive) Connection Type: Split Installation: Freestanding Certification: CE, ISO,CCC,SGS Place of Origin: Jiangsu China (Mainland) Brand Name: SKYLIGHT Model Number: SLCLS Use1: cleaning and washing Use2: pool heating system color: white collector: heat pipe collectors type: split vaccum tube working pressure: 0.8Mpa Testing pressure: 1.2Mpa keyword: solar water heaters

Product Features:

1)Split pressurized heat pipes Solar Water System

2) Manufacture since 1998

3) Free training, no worry

Business Terms:

Price Terms:FOB,CIF,EXW

Payment Terms: T/T,Western Union,MoneyGram,L/C

Minimum Order: Negotiatable

Delivery Port: Customized

Contact Supplier
Manufacture since 1998,Split pressurized heat pipes Solar Water System(SLCLS) With CE,BV,SGS,CCC Approved
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: standard export carton/wooden case

Delivery Detail: 3 days for sample and 10 days for fcl container

Specifications and Product Details:

Components:

Pressurized storage tank, heat pipe solar collector, working station and frame

Skylight Manifold and Heat Pipe Specifications:

  1. Heat pipe wall thickness: 0.6mm
  2. Length and diameter of condenser: 55mm/Φ14mm
  3. Start up speed: 30S
  4. Start up temperature: 25oC
  5. Insulation: Polyurethane + Rock wool
  6. Manifold casing material: Aluminum Alloy
  7. Frame material and thickness: Aluminum Alloy 1.3mm
  8. Inlet Outlet: Φ22 or G3/4 inch compression
  9. Material: TU1
  10. Wall thickness 0.6mm
  11. Temperature can bear(Centigrade) 220
  12. Start up time: 30S
  13. Start up temperature: 25 Centigrade
  14. Diameter and length of condenser 16mm/55cm
  15. Diameter of the tube body 8mm
  16. Vacuum degree: 4*10-3Pa-4*10-4Pa
  17. Heat resistance: 0.02Centigrade/W
  18. Heat transfer rate: >=150w
  19. Best angle of use: 30-60 degree
  20. Max. working pressure: 4MPa
  21. Max. pressure the welding point can bear: 4 Mpa
  22. Temperature range of anti freezing heat pipe: -30Centigrade-300Centigrade
  23. Life expectation 15 years
  24. Warranty 5 years

Skylight Pressure Tank Specs

1. Model: SLPWT 100, 150, 200, 250, 300, 400, 500L

2. Material and thickness of the inner tank: SUS3042B,1.8-2.5mm

3. Material and thickness of the outer shell: Color steel sheet 0.5mm

4. Insulation thickness: 40mm, 50mm

5. Surface area heat exchanger top: 0.4 m2-0.7m2

Working station information

1. It includes controller, Wilo pump and expansion vessel and other needed accessories. It controls the whole system.

2. There are single pipeline and double pipelines two types,

3. Single pipeline: SP106, SP116 and SP118

4. Double pipelines: SP226, SP228 and SP328


Pressurized Tank Model
Inner tank diameterDimensionMaterial and thickness of the inner tank(mm)Material and thickness of the outer shell(mm)Insulation thicknessPacking dimension
SLPWT 100φ368φ450Stainless Steel 1.5Color steel 0.540545×545×1520
SLPWT 150φ385φ470Stainless Steel 1.5Color steel 0.540645×645×1330
SLPWT 200φ478φ570Stainless Steel 1.5Color steel 0.540645×645×1620
SLPWT 250φ478φ570Stainless Steel 1.5Color steel 0.540710×710×1460
SLPWT 300φ550φ630Stainless Steel 1.5Color steel 0.540710×710×1675
SLPWT 400φ550φ630Stainless Steel 1.5Color steel 0.550710×710×1890
SLPWT 500Φ633φ700Stainless Steel 2.0Color steel 0.550770×770×1805
Back-upWorking pressureSurface area heat exchanger topSurface area heat exchanger bottom (m2)Dia. and wall thickness (mm)Installation size of water pipeWeight (reference)
2KW0.8MPa----0.6 m216*1.0NPT3/4"46 Kg
2KW0.8MPa----0.6 m216*1.0NPT3/4"58 Kg
2KW0.8MPa0.4 m20.7 m216*1.0NPT3/4"68 Kg
2KW0.8MPa0.4 m20.7 m216*1.0NPT3/4"75 Kg
3KW0.8MPa0.4 m20.85 m216*1.0NPT3/4"95 Kg
3KW0.8MPa0.7 m20.9 m216*1.0NPT3/4"112 Kg
3KW0.8MPa0.7 m20.9 m216*1.0NPT3/4"122 Kg
Heat Pipe Collector
Model
Aperture AreaN.WG.WMeasurementLoadage
KgsKgsCBMContainer
20GP40GP
SLHPC 58/121.4931.734.80.205122263
SLHPC 58/141.7437.741.30.225111240
SLHPC 58/151.8641.545.40.235106230
SLHPC 58/161.9844.648.80.245102220
SLHPC 58/182.2351.155.80.25598212
SLHPC 58/202.4858.463.60.26594204
SLHPC 58/242.9870.676.80.32577166
SLHPC 58/303.7289.797.50.38565140
Working Station Main functions
01. 8 solar hot water systems for choice;
02. Time display;
03. Temperature difference circulation;
04. Storage tank overheating protection;
05. Emergent stop of system overheating;
06. Frost protection of pipeline and collector;
07. Three periods of time adjustable on pipeline circulation;
08. Three periods of time adjustable on auxiliary heating;
09. Holiday function;
10. Anti-bacteria function;
11. Three speed levels on circulation pump;
12. Display flow rate;
13. Display system pressure.

Manufacture since 1998,Split pressurized heat pipes Solar Water System(SLCLS) With CE,BV,SGS,CCC Approved suppliers    Manufacture since 1998,Split pressurized heat pipes Solar Water System(SLCLS) With CE,BV,SGS,CCC Approved manufacturers