Heat pump water heater
Name: Heat pump water heater(Heating and hot water) | ||||
Model | CWR-12XB | |||
Unit function | Rated heating capacity | kw | 11 | |
BTU | 37543 | |||
Hot water supply | T/h | 0.23 | ||
Rated input power | kw | 2.25 | ||
Rated heaing input current | A | 11.25 | ||
COP | 4.88 | |||
Max running current | A | 17.1 | ||
Power | V/Ph/Hz | 220-240V/380-415V/50Hz | ||
Noise | dB(A) | ≤53 | ||
Dimension | Width | mm | 620 | |
Deepth | mm | 725 | ||
Height | mm | 595 | ||
Weight | kg | 120 | ||
Throttle typ | Electronic expansion valves/thermal expansion valves | |||
Refrigerate | R417A, R407C, R410A | |||
Max outlet water temp | 60°C | |||
Circulation structure | Compressor | Type | Sanyo,Copeland,Daikin,Hitachi,Scroll | |
Locked-rotor current | A | 90 | ||
Security protect functions | Built-in protection device overheating protection, sequence protection, undervoltage protection, delay protect | |||
Water source side heat exchange | Type | Efficient tube to tube heat exchanger | ||
Water flow | m3/h | 1.42 | ||
Water pressure down | kPa | 10 | ||
Pipe size | Inch | 3/4 | ||
Hot water side heat exchange | Type | Efficient tube to tube heat exchanger | ||
Water flow | m3/h | 1.81 | ||
Water pressure down | kPa | 10 | ||
Pipe size | DN | 3/4 | ||
http://clitech.en.alibaba.com |
product explanation
1 Base frame and extenal panels made of polyester powder coated steel.
2 Extremely compact structure,easy demountable for access.
3 High efficiency compressor with R410A,refrigerant.
4 Reverse cycle valve.
5 Super heater for sanitary hot water.
6 Intelligent controller and adjustment by quickmind microprocessor with possiblity or 6
remote control.
7 Careful protection such as :high pressure ,low
pressure.overheating,overload,antifreezing,phase order,discharge temp ,etc.
8 water flow switch for water flow protection.
9 Water side equiped with efficient tube in tube heat exchanger.
10 Themostatic expansion valve
11 General testing and operational test carried out for every unit before package in the
factory.
Rated hot water working condition:water-source side water inlet temp is 15°C,inital temp of hot water is 15°C,termination temp of hot water is 55°C.