Compact design
underfloor house heating or radiator
Heat pump meeting EU standard
Price Terms:FOB,CIF,EXW
Payment Terms: T/T,Western Union,MoneyGram,L/C
Minimum Order: Negotiatable
Delivery Port: Customized
Contact SupplierPackaging Detail: Qualified plywood case
Delivery Detail: Within 25 days
CWR series Ground source heat pump (CWR-08 to CWR-48),
1 Pressurized system design to keep hot water at consistant temperature all the time.
2 100% water circulation of the water source heat pump design
3 Electric protection class IPX4
This Clitech water source heat pump CWR is applicable for different installation conditions of deep underground water system, shallow ground water system and water pipe laying in soil system.
System introduction:
1 Scroll compressor inside.
2 Compact structure, easy demountable for access.
3 Environment friendly refrigerant of R410A or R417A is available.
4 Intelligent controller adjustment by quickmind microprocessor.
5 Four way directional valve.
6 Careful protections like high/low pressure protection, water flow switch protection, overheating protection, overload protection and so on.
7 Fault self-checking function
Control panel:
Technical Parameters:
Geothermal Heat Pump 22KW | |||
Model | CWR-24 | ||
Rated heating capacity | kw / BTU | 21.6 / 75086 | |
Hot water supply | T/h | 0.46 | |
Rated heating input power | kw | 4.58 | |
Rated heatng input current | A | 9.16 | |
COP | kw/kw | 4.72 | |
Power source | V/Ph/Hz | 400V3N/50HZ | |
Noise | dB(A) | ≤55 | |
Maximum outlet water temperature | 60°C | ||
Dimension | mm | W680*D795*H720 | |
Unit weight | kg | 155 | |
Throttle type | Electronic /thermal expansion valves | ||
Water source side heat exchanger | Type | Efficient tube in tube heat exchanger | |
Water flow | m3/h | 2.93 | |
Water pressure drop | kPa | 12 | |
Pipe size | DN | 25 | |
Hot water side heat exchanger | Type | Efficient tube in tube heat exchanger | |
Water flow | m3/h | 3.17 | |
Water pressure drop | kPa | 12 | |
Pipe size | DN | 25 | |
Water side maximum working pressure | kPa | 1000 |
Rated heating working condition: water source side heat exchange inlet water temp. is 15DegC, hot water side heat exchange beginning temp is 15DegC and ending temp is 55DegC.