Air source heat pump water heater
hot water and house heating
connect to radiator or underfloor pipes
Price Terms:FOB,CIF,EXW
Payment Terms: T/T,Western Union,MoneyGram,L/C
Minimum Order: Negotiatable
Delivery Port: Customized
Contact SupplierPackaging Detail: Qualified wooden case
Delivery Detail: within 25 days
Advantages of Air-conditioner and water heater integrated unit(air source)----CAM-40:
1) It can not only work as a air conditioner,but also by the same time provide your with hot water;Also it can run separately,as an air conditioner or a water heater.
2) Safe and convenient to use: water and electricity are seperated section.
3) LCD display controller, convenient to operate and control.
4) Qualified components:Branded compressor(Sanyo, Copeland), Emerson expansion valve,Efficient tube in tube heat exchanger, durable and low noise Nylon fans.
Technical Parameters:
Air conditioner and water heater integrated unit(air source) | |||
Model | Unit | CAM-40 | |
A/C cooling with water heater | Cooling capacity | KW / BTU | 25.9 / 88372 |
cooling Water flow | M3/H | 4.45 | |
Heating capacity | KW / BTU | 33 / 112596 | |
heating water flow | T/H | 5.68 | |
Rated input Power | KW | 7.40 | |
Rated current | A | 14.20 | |
EER+COP | 7.96 | ||
Heating(hot water) | Heating capacity | KW / BTU | 38 / 129656 |
water flow | T/H | 0.82 | |
Rated input power | KW | 8.15 | |
Rated current | A | 15.53 | |
COP | 4.66 | ||
A/C cooling | Cooling capacity | KW / BTU | 24.8 / 84618 |
water flow | M3/H | 4.27 | |
Rated input power | KW | 8.60 | |
Rated current | A | 15.20 | |
A/C heating | Heating capacity | KW / BTU | 26.4 / 90078 |
Water flow | M3/H | 4.54 | |
Power | KW | 8.00 | |
Rated heating current | A | 15.20 | |
Max output water temp | °C | 60°C | |
Power source | V/PH/HZ | 380V/3N /50HZ | |
Noise | DB(A) | ≤50 | |
Dimensions | MM | W1450*D780*H1010 | |
Weight | KG | 340 |
Testing condition:
1. Rated hot water working conditions: air source side air inlet dry bulb temp is 20°C, wet bulb temp is 15°C,initial temp of hot water is 15°C, termination temp of hot water is 55°C.
2. Rated cooling working conditions: air source side air inlet temp is 35°C, use-side water inlet temp is 12°C, outlet temp is 7°C
3. Rated heating working conditions: air source side air inlet dry buld temp is 7°C, wet bulb temp is 6°C, use-side water inlet temp is 40°C,outlet temp is 45°C
4 Cooling with heating working conditions: initial temp of hot water is 15°C, termination temp of hot water is 55°C, air condition water side water inlet temp is 12°C, outlet temp is 7°C